Digium AEX800 Bedienungsanleitung Seite 39

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 69
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 38
Chapter 3: Configuration
3. Specify the channel definitions. The format is:
<device> = <channel list>
A list of valid devices are specified in the sample system.conf file.
If your card has any red FXO modules, add the following to
system.conf:
fxsks =
fxsks uses kewlstart signalling, which is loopstart signalling with disconnect
supervision. For example, a TDM808E card would be configured as the
following:
fxsks = 1-8
OR
fxsks = 1,2,3,4,5,6,7,8
You should have identified the type of 800 Series card when you received it.
If you are not sure, refer to
Module Identification on page 22 for
assistance.
Note: The 800 Series cards do not support Ground Start signaling.